Custom Systems
Portable FID VOC analyzer for discontinuous measurement of total hydrocarbons (VOC). In fixed source discharge. Typical applications include emission testing for solvent use and combustion processes, engine emissions, and VOC emission reduction systems.

Our team of system assembly experts have many years of professional experience
Method of transporting Gas Samples from the ‘point of source’ to the Analysers. Using sample lines, sample handling and conditioning components (Heated or Unheated)
-
At the Sample Point
Sample Composition
What gases are present in addition to those of interest
Corrosive or dangerous to health
Sample Temperature, Pressure & Moisture
High Temp sample may require cooled probe or coil
Positive pressure or under depression (extractive)
Heated or unheated sample line
Location of Sample Point & System
Single or multipoint
Type of rack – Indoor (IP23), Outdoor (IP65), Analyser House
Maintenance & Service access
In addition, sample and gas flow rates are adjusted automatically to optimise analyzer performance.
-
Sample Conditioning - Pressurised
Filtration
High Temp or Normal Filters, Coalesce for moisture removal
Distribution (Multigas)
Distribution oven or multipoint selector
Heated or unheated sample line
Cooling
200 Series Cooler / dryer
-
Sample Conditioning - Extractive
Pump
High Temp or Ambient Sample Pump
Filtration
High Temp or Normal Filters, Coalesce for moisture removal
Distribution (Multigas)
Distribution oven or multipoint selector
Cooling
200 Series Cooler / dryer
Typical Applications
Engine Exhaust Systems
Vehicles, Motorcycles or Engines
Process Stacks & Chimneys
Abatement, CEM, Power Gen
VOC Process Applications
Printing, Paint, Solvent recovery
Landfill, Waste Incineration
Tips, Crematorium, Hospitals
-
Heated VOC Multipoint
-
Automotive System
-
CEM System